Show simple item record

dc.contributor.advisorBartels, Kenneth E.
dc.contributor.authorBordelon, Jude Thaddeus
dc.date.accessioned2014-04-16T03:15:48Z
dc.date.available2014-04-16T03:15:48Z
dc.date.issued2010-05-01
dc.identifier.urihttps://hdl.handle.net/11244/9806
dc.description.abstractAn in vitro mechanical study was performed to compare the fatigue properties and loads to failure of four plate designs used to stabilize the tibial plateau leveling osteotomy (TPLO). Seventy-two gapped osteotomy models were created using 3.5mm versions of the following plates: a standard TPLO plate, a low profile TPLO plate, a locking TPLO plate (LocP), and a broad locking TPLO plate (bLocP). The eighteen constructs for each plate design were sub-divided into three identical groups of six. Six constructs were mounted in a materials testing device and subjected to cyclic compressive loading until failure was observed or one million cycles were achieved. Additionally, six constructs of each plate design were tested in compressive axial loading and six others in four-point bending in a load to failure manner. To provide residual strength comparisons, the six constructs undergoing cyclic fatigue compression testing were also tested in axial compressive loading. There were not any significant differences in stiffness between plates tested in axial compressive loading. However, mean loads at failure were higher for the LocP and bLocP constructs. The bLocP had a significantly higher mean stiffness and mean load at failure compared to the other constructs tested in four point bending.
dc.formatapplication/pdf
dc.languageen_US
dc.publisherOklahoma State University
dc.rightsCopyright is held by the author who has granted the Oklahoma State University Library the non-exclusive right to share this material in its institutional repository. Contact Digital Library Services at lib-dls@okstate.edu or 405-744-9161 for the permission policy on the use, reproduction or distribution of this material.
dc.titleIn Vitro Mechanical Comparison of TPLO Plates
dc.typetext
dc.contributor.committeeMemberRochat, Mark C.
dc.contributor.committeeMemberRitchey, Jerry W.
osu.filenameBordelon_okstate_0664M_10836.pdf
osu.collegeCenter for Veterinary Health Sciences
osu.accesstypeOpen Access
dc.description.departmentVeterinary Pathobiology
dc.type.genreThesis
dc.subject.keywordsbiomechanical
dc.subject.keywordscruciate ligament
dc.subject.keywordstplo