Show simple item record

dc.contributor.authorYou, Tian
dc.contributor.authorLi, Xianting
dc.contributor.authorShi, Wenxing
dc.contributor.authorWang, Baolong
dc.contributor.otherIGSHPA Technical/Research Conference and Expo (2017)
dc.date.accessioned2017-03-06T15:38:30Z
dc.date.available2017-03-06T15:38:30Z
dc.date.issued2017
dc.identifieroksd_igshpa_2017_YouT
dc.identifier.urihttps://hdl.handle.net/11244/49342
dc.description.abstractGround heat exchanger (GHE) is an important component of ground coupled heat pump system (GCHP). To calculate the soil temperature around GHE accurately and fast, a refined response factor model (RF model) is proposed. It combines the heat transfer inside and outside the U pipe through the temperature of pipe wall and the heat flux of U pipe. For the RF model, after calculating the response factors by CFD simulation, the soil temperature can be calculated by the deduced analytical equations. The sandbox experiment is built up to validate the the RF model. Based on the experiment, this case is also studied by the numerical simulation and the RF model. Results show that the soil temperature differences between the RF model and the experiment are only -0.21°C ~0.69°C at the 96th time step. The relative errors of the soil temperatures between RF model and numerical simulation at the 1800th time step are only 1.86%~3.94%. RF model consumes 30% time of the numerical simulation for the soil temperature calculation with 1800 time steps and consumes only 1% time of the numerical simulation for that with 350400 time steps. Therefore, the RF model is accurate and fast to calculate the soil temperature around the GHE with fluid inside.
dc.formatapplication/pdf
dc.languageen_US
dc.publisherInternational Ground Source Heat Pump Association
dc.rightsIn the Oklahoma State University Library's institutional repository this paper is made available through the open access principles and the terms of agreement/consent between the author(s) and the publisher. The permission policy on the use, reproduction or distribution of the article falls under fair use for educational, scholarship, and research purposes. Contact Digital Resources and Discovery Services at lib-dls@okstate.edu or 405-744-9161 for further information.
dc.subjectheat exchangers
dc.subjectheat transmission
dc.titleFast and accurate calculation of the soil temperature distribution around ground heat exchanger based on a response factor model
osu.filenameoksd_igshpa_2017_YouT.pdf
dc.identifier.doi10.22488/okstate.17.000509
dc.type.genreConference proceedings
dc.type.materialText


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record