Show simple item record

dc.contributor.advisorBell, Kenneth John
dc.contributor.authorPark, Sunwon
dc.date.accessioned2015-10-19T18:21:12Z
dc.date.available2015-10-19T18:21:12Z
dc.date.issued1975-05-01
dc.identifier.urihttps://hdl.handle.net/11244/20107
dc.description.abstractThe purpose of this study is to propose an optimization procedure which is applicable to the optimization of the heat exchange system. Optimization of a heat exchange system is studied as a three stage problem: optimization of the heat exchangers, optimization of a heat exchange system for a fixed system configuration, and optimal synthesis of a heat exchange system. The Fibonacci search technique is used for the optimum design of a water cooler. The modified simplex method is used for the optimization of a heat exchanger system for a fixed system configuration. Optimal synthesis of the heat exchange system is developed by graphical analysis of a temperature-enthalpy flow rate diagram and a temperature-heat capacity flow rate diagram.
dc.formatapplication/pdf
dc.languageen_US
dc.publisherOklahoma State University
dc.rightsCopyright is held by the author who has granted the Oklahoma State University Library the non-exclusive right to share this material in its institutional repository. Contact Digital Library Services at lib-dls@okstate.edu or 405-744-9161 for the permission policy on the use, reproduction or distribution of this material.
dc.titleOptimization of a Heat Exchange System in a Process Plant
dc.typetext
dc.contributor.committeeMemberEbrar, John H.
osu.filenameThesis-1975-P236o.pdf
osu.accesstypeOpen Access
dc.description.departmentChemical Engineering
dc.type.genreThesis