Dual-excitation multispectral fluorescence lifetime imaging handheld endoscope for label-free metabolic and biochemical imaging of the oral mucosa
| dc.contributor.author | Tortorelli, Gabriel | |
| dc.contributor.author | Cuenca, Rodrigo | |
| dc.contributor.author | Serafino, Michael J. | |
| dc.contributor.author | Caughlin, Kayla | |
| dc.contributor.author | Busso, Carlos | |
| dc.contributor.author | Woo, Victoria L. | |
| dc.contributor.author | Plemons, Jacqueline | |
| dc.contributor.author | Cheng, Yi-Shing L. | |
| dc.contributor.author | Abraham, Celeste | |
| dc.contributor.author | Wang, Ying S. | |
| dc.contributor.author | Hegde, Rashmi | |
| dc.contributor.author | Jo, Javier A. | |
| dc.date.accessioned | 2026-09-21T18:25:13Z | |
| dc.date.issued | 2025-06-09 | |
| dc.description.abstract | This work introduces a dual-excitation, multispectral-detection, frequency-domain fluorescence lifetime imaging (FLIM) handheld endoscopy system for comprehensive autofluorescence imaging of the oral mucosa. The excitation wavelengths and spectral detection channels were selected to preferentially image the fluorescence of endogenous fluorophores relevant for oral epithelial cancer detection. The endoscope dimensions and optical specifications enable direct imaging of oral lesions with minimal patient discomfort. Comprehensive imaging experiments using standard fluorophores demonstrate the capabilities of the FLIM endoscope to measure a wide range of fluorescence lifetimes (0.1-12 ns) with high precision (~100 ps). Clinical in vivo label-free metabolic and biochemical endoscopic FLIM imaging was demonstrated by imaging a malignant oral lesion and healthy mucosa in a patient undergoing a tissue biopsy procedure. | |
| dc.description.notes | © 2025 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement | |
| dc.description.peerreview | Yes | |
| dc.identifier.citation | Gabriel Tortorelli, Rodrigo Cuenca, Michael J. Serafino, Kayla Caughlin, Carlos Busso, Victoria L. Woo, Jacqueline Plemons, Yi-Shing L. Cheng, Celeste Abraham, Ying S. Wang, Rashmi Hegde, and Javier A. Jo, "Dual-excitation multispectral fluorescence lifetime imaging handheld endoscope for label-free metabolic and biochemical imaging of the oral mucosa," Opt. Lett. 50, 3966-3969 (2025) | |
| dc.identifier.doi | 10.1364/OL.561483 | |
| dc.identifier.uri | https://shareok.org/handle/11244/343045 | |
| dc.language | en_US | |
| dc.publisher | Optica Publishing Group | |
| dc.relation.ispartof | Optics Letters | |
| dc.relation.ispartofseries | 50(12), 3966-3969 | |
| dc.relation.uri | https://opg.optica.org/ol/fulltext.cfm?uri=ol-50-12-3966 | |
| dc.rights | I do not wish to apply a Creative Commons license at this time | |
| dc.subject | Fluorescence lifetime imaging | |
| dc.subject | Imaging systems | |
| dc.subject | Optical filters | |
| dc.subject | Optical testing | |
| dc.subject | Spatial resolution | |
| dc.subject | Systems design | |
| dc.title | Dual-excitation multispectral fluorescence lifetime imaging handheld endoscope for label-free metabolic and biochemical imaging of the oral mucosa | |
| dc.type | Article | |
| ou.group | Gallogly College of Engineering::School of Electrical and Computer Engineering |
Files
Original bundle
1 - 1 of 1