Evaluation of Radio Frequency Ablation in Human Left Atrial Tissues for Atrial Fibrillation Using Optical Coherence Tomography

dc.contributor.authorSelvaraj Mercyshalinie, Ebenezar Raj
dc.contributor.authorPatterson, Dylan
dc.contributor.authorMutembei, Bornface
dc.contributor.authorLadymon, Avery
dc.contributor.authorYan, Feng
dc.contributor.authorPandit, Kaustubh
dc.contributor.authorPeek, Hayden
dc.contributor.authorFung, Kar-Ming
dc.contributor.authorZhang, Qinghao
dc.contributor.authorWang, Chen
dc.contributor.authorCui, Yan
dc.contributor.authorLiu, Junyuan
dc.contributor.authorLiu, Ronghao
dc.contributor.authorMartins, Paulo N.
dc.contributor.authorStavrakis, Stravros
dc.contributor.authorZhang, Ke
dc.contributor.authorMiller, David R.
dc.contributor.authorTang, Qinggong
dc.date.accessioned2026-09-25T14:55:39Z
dc.date.issued2025-09-10
dc.description.abstractDespite its widespread adoption, the success of radiofrequency (RF) ablation is often limited by challenges in achieving durable, transmural lesions while avoiding complications such as incomplete ablation or over-ablation. Optical coherence tomography (OCT) offers high-resolution visualization of cardiac tissue, enabling real-time assessment of lesion depth. Therefore, we investigated the impact of RF ablation on donated human left atrial tissue using an OCT imaging system to assess lesion formation in a controlled laboratory setting. RF ablation lesions were created at durations of 20, 40, 60, 80, and 100 seconds (s), and their effects were quantified by calculating the attenuation coefficient from OCT images. To identify tissue regions in the image, a U-Net model was employed for segmentation, achieving a mean intersection over union (IoU) of 0.9748 with an inference time of 82 milliseconds. Our results demonstrated clear differences in tissue response before and after ablation, with distinct lesion characteristics across the tested durations. One-way ANOVA analysis yielded a p-value of 1.09 × 10−8, confirming statistically significant differences among the ablation durations. These findings highlight the potential of SD-OCT for precise, real-time monitoring of ablation effects. Future work aims to integrate OCT with ablation catheters for clinical applications, enhancing the precision of catheter-based treatments for conditions like atrial fibrillation.
dc.description.notes“Financial support was provided by the University of Oklahoma Libraries' Open Access Fund
dc.description.peerreviewYes
dc.identifier.bibliographicCitationEbenezer Raj Selvaraj Mercyshalinie, Dylan O. Patterson, Bornface M. Mutembei, Avery D. Ladymon, Feng Yan, Kaustubh Pandit, Hayden Peek, Kar-Ming A. Fung, Qinghao Zhang, Chen Wang, Yan Cui, Junyuan Liu, Ronghao Liu, Paulo Martins, Stavros Stavrakis, Ke Zhang, David R. Miller, and Qinggong Tang, "Evaluation of radio frequency ablation in human left atrial tissues for atrial fibrillation using optical coherence tomography," Biomed. Opt. Express 16, 4003-4016 (2025)
dc.identifier.doi10.1364/BOE.570328
dc.identifier.urihttps://shareok.org/handle/11244/343176
dc.languageen_US
dc.relation.isPartOfBiomedical Optics Express
dc.relation.isPartOfSeries16(10), 4003–4016
dc.relation.urihttps://opg.optica.org/boe/fulltext.cfm?uri=boe-16-10-4003
dc.subjectOptical coherence tomography
dc.subjectradiofrequency ablation
dc.subjectbiomedical engineering
dc.titleEvaluation of Radio Frequency Ablation in Human Left Atrial Tissues for Atrial Fibrillation Using Optical Coherence Tomography
dc.typeArticle
ou.groupGallogly College of Engineering::Stephenson School of Biomedical Engineering

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
boe-16-10-4003.pdf
Size:
4.11 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
2.01 KB
Format:
Item-specific license agreed upon to submission
Description: