Show simple item record

dc.contributor.authorHan, Ho
dc.contributor.authorKim, Heontae
dc.contributor.authorSun, Wei
dc.contributor.authorMalaska, Mary
dc.contributor.authorMiller, Bridget
dc.date.accessioned2022-04-19T20:18:49Z
dc.date.available2022-04-19T20:18:49Z
dc.date.issued2019-12-09
dc.identifieroksd_han_validationofwearableactivity_2019
dc.identifier.citationHan, H., Kim, H., Sun, W., Malaska, M., & Miller, B. (2019). Validation of wearable activity monitors for real-time cadence. Journal of Sports Sciences, 38(4), pp. 383-389. https://doi.org/10.1080/02640414.2019.1702281
dc.identifier.urihttps://hdl.handle.net/11244/335261
dc.description.abstractThe purpose of this study is to establish evidence of validity for wearable activity monitors providing real-time cadence against a criterion measure. Thirty-six healthy adults, aged 18-65 years, participated in the study. Four activity monitors including 2 watch-based monitors and 2 cadence sensors attaching to shoelaces were tested. Each participant completed the study protocol consisting of 2 distinct components: (1) treadmill protocol and (2) overground protocol. Lin's concordance correlation and mean absolute percentage error (MAPE) were calculated for the comparisons between the criterion and measures of the monitors. Bland-Altman analysis was performed to determine the mean bias and 95% limits of agreement. All activity monitors showed high correlations with the criterion measures (p < .01). Lower correlations were observed at slow walking speeds in the watch-based monitors. In contrast, consistent and strong correlations were found with both cadence sensors regardless of walking speeds (p < .01). Similar patterns were observed in the MAPE scores. Greater than 90% of the participants were able to maintain prescribed walking intensity using real-time cadence. The results suggest that the wearable activity monitors are an acceptable measure of real-time cadence and provide the potential to improve intensity-based prescription of physical activity using the monitors.
dc.formatapplication/pdf
dc.languageen_US
dc.publisherInforma UK Limited
dc.relation.ispartofJournal of Sports Sciences, 38 (4)
dc.relation.urihttps://www.ncbi.nlm.nih.gov/pubmed/31818198
dc.rightsThis material has been previously published. In the Oklahoma State University Library's institutional repository this version is made available through the open access principles and the terms of agreement/consent between the author(s) and the publisher. The permission policy on the use, reproduction or distribution of the material falls under fair use for educational, scholarship, and research purposes. Contact Digital Resources and Discovery Services at lib-dls@okstate.edu or 405-744-9161 for further information.
dc.subject.meshAdolescent
dc.subject.meshAdult
dc.subject.meshAged
dc.subject.meshFitness Trackers
dc.subject.meshHumans
dc.subject.meshMiddle Aged
dc.subject.meshReproducibility of Results
dc.subject.meshRunning
dc.subject.meshWalking Speed
dc.subject.meshYoung Adult
dc.titleValidation of wearable activity monitors for real-time cadence
dc.date.updated2022-04-12T18:20:31Z
osu.filenameoksd_han_validationofwearableactivity_2019.pdf
dc.description.peerreviewPeer reviewed
dc.identifier.doi10.1080/02640414.2019.1702281
dc.description.departmentCommunity Health Sciences, Counseling and Counseling Psychology
dc.type.genreArticle
dc.type.materialText
dc.subject.keywordsCadence prescription
dc.subject.keywordsaccuracy
dc.subject.keywordsactivity devices
dc.subject.keywordscompliance
dc.subject.keywordsClinical Research
dc.subject.keywords1106 Human Movement and Sports Sciences
dc.subject.keywords1302 Curriculum and Pedagogy
dc.subject.keywordsSport Sciences
dc.identifier.authorORCID: 0000-0003-4241-7317 (Han, H)
dc.identifier.authorScopusID: 57191291072 (Han, H)
dc.identifier.authorORCID: 0000-0002-8452-4527 (Kim, H)
dc.identifier.authorScopusID: 57205723554 (Kim, H)
dc.identifier.authorScopusID: 57198850955 (Sun, W)
dc.identifier.authorORCID: 0000-0002-3898-7483 (Malaska, M)
dc.identifier.authorScopusID: 57212313847 (Malaska, M)
dc.identifier.authorScopusID: 57213889559 | 7403945325 (Miller, B)


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record