Date
Journal Title
Journal ISSN
Volume Title
Publisher
The collective data associated with this article presents the biaxial mechanical behavior for six smaller, delimited regions of the mitral valve and tricuspid valve anterior leaflets. Each data set consists of five columns of data, specifically: (i) biaxial testing protocol ID, (ii) circumferential stretch, (iii) radial stretch, (iv) circumferential membrane tension, and (v) radial membrane tension. For further elaboration regarding methodologies or results of the biaxial mechanical characterization please refer to the companion article Laurence, 2019.
Description
Keywords
Citation
Related file
Notes
Sponsorship
Support from the American Heart Association Scientist Development Grant (SDG) Award (16SDG27760143) is gratefully acknowledged. CHL was in part supported by the institutional start-up funds from the School of Aerospace and Mechanical Engineering (AME) and the research funding through the Faculty Investment Program from the Research Council at the University of Oklahoma (OU). DL, CR, and SJ were supported by the Mentored Research Fellowship from the Office of Undergraduate Research at OU. DL and CR were supported by the Undergraduate Research Opportunities Program from the Honors College at OU. We also acknowledge undergraduate researchers Jacob Richardson and Ryan Bodlak for their assistance with the biaxial mechanical testing.