Show simple item record

dc.creatorKamel, Amr
dc.creatorKalluri, Phani
dc.creatorBush, Thomas D. Jr
dc.date.accessioned2018-09-06T21:52:18Z
dc.date.available2018-09-06T21:52:18Z
dc.date.issued1993-6
dc.identifier.govdocFHWA-OK-93-02
dc.identifier.otherOklahoma Department of Transportation State Planning and Research item number 2700
dc.identifier.urihttps://hdl.handle.net/11244/301647
dc.description.abstractThe performance of a generic silane penetrating water repellent material was evaluated using alternate test procedures . Field variables introduced into the laboratory tests included: 1) concrete mix design, 2) concret~ surface finish , and 3) curing and cleaning methods prior to the application of silane. Two basic laboratory tests series were used: 1) Oklahoma Department of Transportation tests, and 2) a series based on NCHRP 244 Series II. Silane performance was evaluated with respect to depth of penetration, absorption, water vapor permeability, and chloride ingress. One mix type examined was similar to standard reference concrete often used in laboratory testing (w/c=0.49) . The other two mixes represented structural deck concrete (w/c=0.44) and high density overlay (w / c = 0.33). Concrete surface finishes studied included smooth/broom and tine. Curing methods examined included use of a linseed oil emulsion compound, use a white pigmented membrane compound, and self-curing. Methods used to clean the concrete surface prior to treatment were dry shot-blasting, high pressure water washing, and no cleaning. Results indicated the need to represent field conditions (particularly mix design) to the extent possible in order to predict better field performance with laboratory tests. Also, relative performance of some mixes was affected by the test procedure performed.
dc.format.extent99 pages
dc.format.extent27,863,662 bytes
dc.format.mediumapplication.pdf
dc.languageen_US
dc.relation.ispartofseriesNo
dc.relation.requiresAdobe Acrobat Reader
dc.titleExperimental products and equipment for highway construction and maintenance annual report January 1993 (FHWA-OK-93-01) 2700
dc.typeTechnical Report
dc.description.versionFinal Report, July 1990-June 1993
dc.description.peerreviewNo
dc.type.materialtext
dc.subject.keywordsSilane
dc.subject.keywordsWeatherproofers
dc.subject.keywordsBridge deck maintenance
dc.subject.keywordsCuring
dc.subject.keywordsConcrete cleaning
dc.contributor.sponsorOklahoma Department of Transportation. Materials and Research Division. Office of Research & Implementation


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record