Show simple item record

dc.contributor.authorKim, Min-Jun
dc.contributor.authorLee, Seung-Rae
dc.contributor.authorLim, Hwan-Hui
dc.contributor.authorJeon, Jun-Seo
dc.contributor.authorKim, Min-Seop
dc.contributor.otherIGSHPA Research Track (2018)
dc.date.accessioned2018-08-28T17:58:55Z
dc.date.available2018-08-28T17:58:55Z
dc.date.issued2018
dc.identifieroksd_ighspa_2018_kim
dc.identifier.urihttps://hdl.handle.net/11244/301570
dc.description.abstractGeothermal energy has been widely used over the world instead of fossil fuel for environmental merits. A ground-source heat pump (GSHP) system utilizes a constant ground temperature to absorb heat during winter and to emit heat in summer. The GSHP system can be devieded into a closed type system and an open type system. The closed type system using a horizontal ground heat exchanger (HGHE) is relatively inexpensive and easy to install compared to the other types of systems. Among the types of HGHEs, since a horizontal spiral-coil type GHE has the advantageous arrangement for heat exchange between the heat exchanger and surrounding ground, it is the most effective type of the HGHE in terms of thermal performance. However, the thermal performance of a horizontal spiral-coil type GHE critically depends on its dimension which consists of the radius and pitch of a spiral, and thus it is important to accurately analyze how the radius and pitch affect the thermal performance of the horizontal spiral-coil type GHE. Therefore, this paper investigated the thermal performance of a horizontal spiral-coil type GHE according to its diverse shapes to suggest a beneficial design specification of the horizontal spiral-coil type GHE. In order to evaluate the thermal performance of the heat exchanger, a spiral-coil type HGHE was installed in a steel box of which the size was 5 m x 1 m x 1 m filled with dry Joomunjin standard sand, and a thermal response test (TRT) was conducted for 30 hours continuously. Besides, a numerical analysis was performed for its verification and a parametric study of the horizontal spiral-coil GHE using a numerical program which is based on a finite element method (FEM). As a result, in case that the pitch of the horizontal spiral-coil type GHE was more than 0.6 m, there was no more significant benefit in the thermal performance.
dc.formatapplication/pdf
dc.languageen_US
dc.publisherInternational Ground Source Heat Pump Association
dc.rightsIn the Oklahoma State University Library's institutional repository this paper is made available through the open access principles and the terms of agreement/consent between the author(s) and the publisher. The permission policy on the use, reproduction or distribution of the article falls under fair use for educational, scholarship, and research purposes. Contact Digital Resources and Discovery Services at lib-dls@okstate.edu or 405-744-9161 for further information.
dc.titleThermal performance evaluation of horizontal spiral coil-type ground heat exchangers
osu.filenameoksd_ighspa_2018_kim.pdf
dc.identifier.doi10.22488/okstate.18.000031
dc.type.genreConference proceedings
dc.type.materialText


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record