Experimental setup to measure the heat-exchange processes by controlling thermal and hydraulic conditions
(International Ground Source Heat Pump Association, 2018)
The design of a Borehole Heat Exchanger (BHE) is based on the evaluation of the thermal exchange capacity of the whole system constituted by the probes and the surrounding ground. The energy performance of a BHE mainly ...
Soil thermal conductivity from early TRT logs using an active hybrid optic fibre system
(International Ground Source Heat Pump Association, 2018)
At the Molinella test site in Italy, a monitoring well has been equipped with a hybrid active optical fibre cable down to the depth of 100 m sealed with geothermal grouting. The cored borehole provided a full stratigraphic ...