dc.description.abstractThe objective of this thesis was to find the lowest three natural frequencies of heat exchanger U-tubes by numerical and experimental methods. The results were transformed into a usable form for a heat exchanger design engineer.
dc.formatapplication/pdf
dc.languageen_US
dc.publisherOklahoma State University
dc.rightsCopyright is held by the author who has granted the Oklahoma State University Library the non-exclusive right to share this material in its institutional repository. Contact Digital Library Services at lib-dls@okstate.edu or 405-744-9161 for the permission policy on the use, reproduction or distribution of this material.