dc.contributor.advisor | Erbar, Ruth C . | |
dc.contributor.author | Johnson, Paul Coulter | |
dc.date.accessioned | 2015-08-19T16:06:03Z | |
dc.date.available | 2015-08-19T16:06:03Z | |
dc.date.issued | 1988-05-01 | |
dc.identifier.uri | https://hdl.handle.net/11244/15623 | |
dc.description.abstract | Due to escalating fuel prices beginning in the early 1970's refinery, petrochemical, and chemical plant management personnel have had to shift their philosophy from one of building larger production units to that of upgrading or retrofitting existing units to improve their energy efficiency. In order to examine one possiblity of a distillation retrofit, a case study has been performed on the installation of a retrofitted intermediate reboiler on an industrial depropanizer for minimum energy consumption. | |
dc.format | application/pdf | |
dc.language | en_US | |
dc.publisher | Oklahoma State University | |
dc.rights | Copyright is held by the author who has granted the Oklahoma State University Library the non-exclusive right to share this material in its institutional repository. Contact Digital Library Services at lib-dls@okstate.edu or 405-744-9161 for the permission policy on the use, reproduction or distribution of this material. | |
dc.title | Case Study on the Installation of a Retrofitted Intermediate Reboiler on an Industrial Depropanizer for Minimum Energy Consumption | |
dc.type | text | |
dc.contributor.committeeMember | Bell, Kenneth John | |
dc.contributor.committeeMember | Robinson, Robert S., Jr. | |
osu.filename | Thesis-1988-J68c.pdf | |
osu.accesstype | Open Access | |
dc.description.department | Chemical Engineering | |
dc.type.genre | Thesis | |