dc.description.abstractHybrid Ground-Source Heat Pump (HGSHP) systems have been introduced as an alternate system configuration to remedy the current financial hurdles associated to the installation of geo-exchange technology. However, there still remains potential for increased economic feasibility with the addition of improved system control. This study introduces an operational strategy referred to as an 'Off-Peak Ground Pre-Cool', employing time-of-use conscious operating logic to facilitate artificial bore-field pre-conditioning. Artificially pre-cooling a system's bore-field during an off-peak operating bracket allows for improved thermal characteristics for the following peak period. With improved bore-field thermal characteristics during peak periods, cooling mode operation can be exploited more efficiently, resulting in a reduction in peak power consumption and operating costs. This study presents a preliminary evaluation of the impact the proposed off-peak ground pre-cool strategy has on the operation of a HGSHP system, simulated for a mid-rise multi-residential facility located in Toronto, Canada. Two analyses are presented simulating the strategy's impact as a function of pre-cool duration and hybrid system proportions. This study explores the potential benefit that a proactive bore-field pre-condition poses for the operation of a HGSHP system, intending to concurrently address improving system economics and aid in the balancing of the electrical grid.
dc.formatapplication/pdf
dc.languageen_US
dc.publisherInternational Ground Source Heat Pump Association
dc.rightsIn the Oklahoma State University Library's institutional repository this paper is made available through the open access principles and the terms of agreement/consent between the author(s) and the publisher. The permission policy on the use, reproduction or distribution of the article falls under fair use for educational, scholarship, and research purposes. Contact Digital Resources and Discovery Services at lib-dls@okstate.edu or 405-744-9161 for further information.
dc.subjectground source heat pump systems
dc.titleEffect of an off-peak ground pre-cool control strategy on hybrid ground-source heat pump systems