2018-08-062018-08-062001-2FHWA-OK-00-03Oklahoma Department of Transportation State Planning and Research item number 2132https://hdl.handle.net/11244/301361In September 1999,Bridges"A'." and "B" of contract TBOI-0035-1(110)044 were overlaid with a silica fume concrete surface. ODOT has been exploring ways to stop or slow chloride-induced corrosion of uncoated reinforcing steel in bridge decks. Silica fwne concrete additive has demonstrated success in reducing chloride intrusion. After one year of testing. the ride quality decreased slightly. skid test results show an adequate amount of friction characteristics. and both bridges in good condition base on based on reinforcing steel corrosion activity. Overall. silica fume modified PCC overlay is perfonning well.24 pages30,495,086 bytesapplication.pdfEvaluation of silica fume high density thin bonded overlays - interim report (FHWA-OK-00-03) 2132Technical ReportSilica fumeHalf-cell testingCorrosionHairline cracks